<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-11 08-26-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 40 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
5 kHz 44 kHz 18449 0,0867
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,6 dBr -0,99 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 8:26, 11.06.2024
RT
"Ranni Plus - Moderuji Lukas Matoska a Pavlina Necaskova. "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 44 kHz MIN: 5 kHz % above 77 kHz: 0,0867 Acquired: 2024/06/11 8:26:51 Total samples: 18449 Equivalent time: 0:15:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,5 dBr MIN: -1,6 dBr AVE: -0,99 dBr % above 0,2 dBr: 0,0 Last value: -1,5 dBr (2024/06/11 8:26:51) 08:12 08:14 08:16 08:18 08:20 08:22 08:24 08:26 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality